MESC 's top priority is to produce a value product to international standards and to employ materials which helps in controlling pollution.
Products are manufactured, tested and certified by institutions such as:
- Underwriters Laboratories ( UL) - USA
 |
UL 1277: 9Cx12AWG, Type TC, CU/XLPE/PVC, 600V |
 |
UL 13: 2Cx12AWG, Type PLTC, 300V |
 |
UL 1581 VW-1: 2Cx12AWG, Type PLTC, 300V |
 |
UL 1666: 4Px24AWG, LAN Cat 5e UTP |
 |
UL 1424,UL 1666: 2Cx20AWG, FPLR Shielded CU/PVC/PVC, 300V |
 |
UL 444: 4Px24AWG, LAN Cat 5e UTP |
 |
UL 444, CSA,C22.2 No 214: 4Px24AWG, LAN Cat 5e UTP (CMP) |
 |
UL 444, CSA,C22.2 No 214: 4Px24AWG, LAN Cat 5e UTP (CMR) |
 |
UL 83:TW,THW,THW-2,THHW,THHN,THWN,THWN-2, 600V |
- British Standards Institution (BSI) - UK
 |
BS 5308-1: 10Px1.5mm2, (I+O) CU/PE/LC/SWA/PVC, 300/500V |
 |
BS 5308-1, IEC 60502, BS EN 12548: 10Px1.0 mm2, (I+O) CU/XLPE/LC/SWA/PVC, -300/500V |
 |
BS 5308-1: 10Px1.5mm2, CU/PE/SWA/PVC, 300/500V |
 |
BS 5308-2: 10Px1.5mm2, CU/PVC/SWA/PVC, 300/500V |
 |
BS 6004: 1Cx2.5,1Cx 70mm2, NYA, 450/750V |
 |
BS 6387(Cat C): 10Px1.0mm2, (I+O) CU/MICA/LSHF/LC/SWA/LSHF, 300/500V |
 |
BS 6387(Cat W):10Px1.0mm2, (I+O) CU/MICA/LSHF/LC/SWA/LSHF, 300/500V |
 |
BS 6387(Cat Z): 10Px1.0mm2, (I+O) CU/MICA/LSHF/LC/SWA/LSHF, 300/500V |
 |
EEMUA 133, BS 5467: 37Cx2.5mm2, CU/XLPE/LC/SWA/PVC, 600/1000V |
 |
ICEA S82-552 (Oil Immersion Test): 1Px2.5 mm2, CU/PVC/LC/SWA/PVC, 600/1000V |
 |
IEC 60502, SEC 5/7: 24Cx2.5mm2, CU/XLPE/SWA/PVC, 600/1000V |
 |
IEC 60502, SEC 5/8: 2Cx10mm2, CU/PVC/SWA/PVC, 600/1000V |
 |
IEC 60502, SEC EWR: 19Cx1.5mm2, (N2XCY)CU/XLPE/CU (TAPE+WIRE)/PVC, 600/1000V |
 |
IEC 60502: 3Cx1.5mm2, CU/PVC/PVC, 600/1000V |
 |
CCEI IEC 60332-1-1:2004 and 60332-1-2 2004 |
 |
IEC 60332-3-22:2000 category A and IEC 60332-3-23:2000 category B |
 |
BS 6387:1994, Resistance to Fire alone category 'C" at 950 degree C for 3 hours |
 |
BS 6387:1994, Resistance to Fire with mechanical shock category "Z" test only |
 |
BS 6387:1994, Resistance to Fire with water category "W" test only |
 |
UL 1277:(Ageing, Oil Resistance & Cold Bend tests):1Px12AWGCU/PVC/PVC, 600V |
 |
QA/95/2087, BS 5308-2, BS 7655:5Px1.0+1.0mm2, CU/PVC/PVC Braided, 300/500V |
- Italian Standard Institution (IMQ) - Italy
- VDE Testing and Certification Institute (VDE) - Germany
 |
DIN VDE 0815, DIN VDE 0815A: 2Px0.5mm2 ,BD JE-LIYCY0, 225V |
 |
DIN VDE 0815, DIN VDE 0815A: 2Px0.8mm2, BD JE-Y(ST)Y0, 225V |
 |
VDE 0281-13 HD21.13S1: 12Cx0.75mm2, HO5VV5-F CU/PVC/PVC, 300/500V |
 |
VDE 0281-13 HD21.13S1: 3Cx1.5mm2, HO5VV5-F CU/PVC/PVC, 300/500V |
- Canadian Standards Association (CSA) - Canada
- KEMA - Netherlands
 |
BS 5308-2, BS 6746, IEC 60502, IEC 60332-1: 1Px1.0mm2, CU/PVC/PVC, 300/500V |
 |
BS 5308-2, BS 6746, IEC 60502, IEC 60332-1: 5Cx1.0mm2, CU/PVC/PVC, 300/500V |
- Third Party Testing (3P) - Denmark
- Warrington Fire Research Centre (WFRC) - UK
 |
ASTM D 2863: 19Cx2.5 mm2, CU/XLPE/SWA/PVC (APC 9 FR), 600/1000V |
 |
ASTM D 2863: 8Px1.0 mm2, CU/XLPE/LSHF/SWA/LSHF (Crosspolimeri PR 420), 600/1000V |
 |
ASTM D 2863: 5Px1.0 mm2, CU/MICA/LSHF/SWA/LSHF(Megalon S500), 300/500V |
 |
IEC 60331: 2Cx18AWG, CU/LSHF/LSHF, 450/750V |
 |
IEC 60331: 1Px1.5mm2, CU/LSHF/LSHF, 300/500V |
 |
IEC 60332-3 Cat C: 2Cx1.5mm2, HFFR CU/PVC/PVC, 600/1000V |
 |
IEC 60332-3 Cat C: 10Px1.0mm2, Type PLTC, CU/XLPE/SWA/PVC, 300V |
 |
IEC 60754-1: APC 9 FR |
 |
IEC 60754-1: Crosspolimeri SK/3C LA NAT |
 |
IEC 60754-1: Megalon S500 |
 |
IEC 60754-1: 2Cx1.5mm2, HFFR CU/PVC/PVC, 600/1000V |
 |
IEC 60754-1: 12Cx2.5mm2, CU/MICA/XLPE/SWA/LSHF, 600/1000V |
 |
IEC 60331-21: 12Cx2.5mm2, CU/MICA/XLPE/SWA/LSHF, 600/1000V |
 |
IEC 60332-3 Cat C: 6Px1.0mm2, CU/XLPE/SWA/PVC, 300/500V |
 |
IEC 61034: 10Px1.5mm2, CU/XLPE/SWA/LSHF, 300/500V |
 |
ISO 4589-2: 6Px1.0mm2, CU/XLPE/SWA/PVC, 300/500V |
- Cable Technology Laboratories Inc (CTL) - USA
- Saudi Arabian Standards Organization (SASO) - KSA
- Shriram Institute for Industrial Research (SIIR) - India
- Saudi Aramco (SAAR) - KSA
- RW Data Ltd (RW) - UK
- Ministry of Electricity and Water (MEW) - Kuwait
- King Saud University (KSU) - KSA
|
|